How It Works
When power is supplied to the motor (via either an on-board timer on controller or by customer-supplied power) the motor runs the gear pump. As the motor turns, the gear pump pulls lubricant in from the reservoir and delivers pressurized lubricant to the distribution network via the outlet(s) in the top plate. Pressurizing the distribution network forces all the resistance fittings in the system to open, allowing lubricant to flow to the friction points. The resistances fittings continue to flow and the pump builds pressure until pressure relief valve setting is reached (75psi). Once the motor is shut off, pressure in the distribution network returns to near 0psi. This actuates a quick dump valve which relieves the line pressure back into the reservoir.
|
| Technical Specifications |
|
|
| Output volume - 115VAC, 230VAC (max.) |
200cc/min @ 60Hz (167cc/min @ 50Hz) |
| Output volume - 24VDC (max.) |
250cc/min |
| Output volume - Three phase (max.) |
200 or 500cc/min @ 60Hz; 167 or 415cc/min @ 50Hz |
| Output pressure (max.) |
5 bar (75psi) |
| Pressure switch resetting |
Optional, closes at 1.4 ±0.3 bar (20 ±5 psi) |
| Lubricant viscocity |
Oil: 20 to 1500 cp |
| Reservoir fill screen (oil only) |
40 mesh, removable |
| Reservoir volume |
1.8 Liter, 2.7 Liter, 6.0 Liter, 12.0 Liter |
| Reservoir material |
Clear ABS Plastic for 1.8, 2.7, and 6.0L, Steel for 12.0L |
| Motor Voltage Options |
115VAC, 230VAC, 50/60 Hz, 24VDC (single phase)
230/415VAC 50 Hz, 260/480VAC 60 Hz (three phase) |
| Motor power requirements |
Approximately 140W |
| Operating temperature range |
+5°C through +40° C (+40°F through +105°F) |
| IP rating |
IP-54 |
| Electrical fitting |
Liquid tight |
| Output connection |
G 1/4 BSPP |
| Single (main) feed line |
6mm OD minimum recommended |
|